NEW! Audit and checklist guidance - Below Ground Sewer

Audit: Below Ground Sewer

(Excluding effluent disposal systems)

  • Download the template here


Phase 1

󠄀

Have documents been sited which show building consent has been granted?

󠄀

Are the materials used fit for their intended purpose?

󠄀

Where required has provision been made for a drain installed in unstable/water charged ground?

󠄀

Does the excavation comply with the WorkSafe Good Practice guidelines?

󠄀

Is surcharge protection provided (e.g. overflow relief gully or reflux valve)?

󠄀

Is the drain adequately vented?

󠄀

Is the drain connected to the correct connection(s)?

󠄀

Does the bedding installation comply?

󠄀

Does the bedding material comply?

󠄀

Does the drain have the correct gradient?

󠄀

Did the drain pass the correct test? (e.g. testing listed in G13/AS2 6.1)


Phase 2

󠄀

Have the required concrete supports for drainage fittings been installed?

󠄀

Are access chambers of the approved size/materials?

󠄀

Does the installation comply with the proximity to other services?

󠄀

In the drain protected from the entry of stormwater/groundwater (e.g. is the overflow relief gully the correct height above the surface)?

󠄀

Does the drain have the minimum cover?

󠄀

Does the backfill material comply?

󠄀

If the drain has been installed in an easement, is the installation compliant with the requirements of the easement?

󠄀

Do the inspection provisions comply?

 

󠄀

Is the drain pipework appropriately sized?

󠄀

Is the design of the drain to an acceptable standard?                                                                                        


References

Does the installation comply with the minimum industry standards?

  • G13 Foul water
  • AS/NZS 3500.2 Plumbing and drainage Part 2: Sanitary plumbing and drainage
  • The consented plans
  • The relevant manufacturer’s instructions
  • B2 Durability

Please note

Other standards may be applicable to the installation and should be referenced as required. Additionally, audit items may alter dependant on the actual work conducted and the final installation.

Practitioners should ensure they are using the relevant edition of the prescribed building code compliance documentation, at the time of installation.

NEW! Audit and checklist guidance: below ground stormwater

  • Download this audit check list  

    Phase 1

    󠄀

    Have documents been sited which show building consent has been granted?

    󠄀

    Are the materials used fit for their intended purpose?

    󠄀

    Is the discharge capacity adequate for the catchment area?

    󠄀

    Where required has provision been made for a drain installed in unstable/water charged ground?

    󠄀

    Does the excavation comply with the WorkSafe Good Practice guidelines?

    󠄀

    Where required is a reflux valve installed?

    󠄀

    Where required does the drain have overflow provision?

    󠄀

    Is the drain connected to the correct connection(s)?

    󠄀

    Does the bedding installation comply?

    󠄀

    Does the bedding material comply?

    󠄀

    Does the drain have the correct gradient?

    󠄀

    Did the drain pass the correct test? (e.g. testing listed in E1/VM1 8.0)

     

    Phase 2

    󠄀

    Where required have inspection openings been installed?

    󠄀

    Have the required concrete supports for drainage fittings been installed?

    󠄀

    If a retention system is installed, has a surcharge outlet point been provided?

    󠄀

    Does the installation comply with the proximity to other services?

    󠄀

    Does the backfill material comply?

    󠄀

    Does the drain have the minimum cover?

    󠄀

    Is the drain constructed in an appropriate size?

     

     

     

    󠄀

    Have appropriate covers been used on inspection risers?

    󠄀

    Is the design of the drain to an acceptable standard?                                                                                        

    󠄀

    If the drain has been installed in an easement, is the installation compliant with the requirements of the easement?

    󠄀

    Where required has the soak pit been appropriately sized?

    󠄀

    Where required has the soak pit been appropriately constructed?

    󠄀

    Where required have the sump(s) been appropriately sized?

    󠄀

    Where required are the sump(s) correctly constructed?

     

    References

    Does the installation comply with the minimum industry standards and legislation?

    󠄀

    E1 Surface Water

    󠄀

    The Resource Management Act 1991

    󠄀

    The consented plans

    󠄀

    The relevant manufacturer’s instructions

    󠄀

    B2 Durability

     

    Please note

    Other standards may be applicable to the installation and should be referenced as required. Additionally, audit items may alter dependant on the actual work conducted and the final installation.

    Practitioners should ensure they are using the relevant edition of the prescribed building code compliance documentation, at the time of installation.

     

Tech sheets:

Governing legislation and important compliance documents

Click through to the Legislation Hub 

In this hub we keep you informed on governing legislation and important compliance documents that assist you to keep it legal.

You can also find links to the policies adopted by the Board here.

Health and Safety at Work Act

The working together on health and safety presentation provides you with the basic facts you need to know about the Health and Safety at Work Act (HSWA). It covers the main concepts at a high level.

Supervision guidelines

Everything you need to know it get it right

Templates are included in this download

The burden of Legionnaires' disease in New Zealand

The burden of Legionnaires’ disease in New Zealand

(LegiNZ): a national surveillance study

Summary

Background Legionnaires’ disease is under-diagnosed because of inconsistent use of diagnostic tests and uncertainty
about whom to test.

We assessed the increase in case detection following large-scale introduction of routine PCR testing of respiratory specimens in New Zealand.

Methods LegiNZ was a national surveillance study done over 1-year in which active case-finding was used to maximise the identification of cases of Legionnaires’ disease in hospitals.

Respiratory specimens from patients of any age with pneumonia, who could provide an eligible lower respiratory specimen, admitted to one of 20 participating hospitals, covering a catchment area of 96% of New Zealand’s population, were routinely tested for legionella by PCR.

Additional cases of Legionnaires’ disease in the hospital were identified through mandatory notification.

Findings Between May 21, 2015, and May 20, 2016, 5622 eligible specimens from 4862 patients were tested by PCR.

From these, 197 cases of Legionnaires’ disease were detected. An additional 41 cases were identified from notification
data, giving 238 cases requiring hospitalisation.

The overall incidence of Legionnaires’ disease cases in hospital in the study area was 5·4 per 100 000 people per year, and Legionella longbeachae was the predominant cause, found in 150 (63%) of 238 cases.

Interpretation The rate of notified disease during the study period was three-times the average over the preceding 3 years.

Active case-finding through systematic PCR testing better clarified the regional epidemiology of Legionnaires’
disease and uncovered an otherwise hidden burden of disease.

These data inform local Legionnaires’ disease testing strategies, allow targeted antibiotic therapy, and help identify outbreaks and effective prevention strategies.

The same approach might have similar benefits if applied elsewhere in the world.
Funding Health Research Council of New Zealand.

Print the full study:

The burden of Legionnaires’ disease in New Zealand download

 

Advance your career and earning potential by upskilling

In the current climate, business and tradespeople may want to consider ways to diversify their skill set and provide new earning opportunities.  Here are a few opportunities businesses and tradespeople may want to consider.


Associated Tradesperson 

Become an Associated Tradesperson. This class of registration sits under the Electrical Workers Registration Board (EWRB).

It allows registered plumbers and/or gasfitters to do a limited amount of restricted electrical work relating to their trade.

Those that hold this registration can do maintenance and replace fittings that have an electrical rating of not more than 250 volts and 16 amperes on a limited amount of appliances.

For example, an Associated Tradesperson Plumber can replace an element in a storage water heater; an Associated Tradesperson Gasfitter can replace electrical fittings that form part of gas fired equipment; or an Associated Tradesperson Plumber/Gasfitter can do both.

Find out more at


Independent Qualified Person (IQP) backflow prevention

Become an IQP for testing backflow prevention devices. An IQP can test backflow prevention devices, but only an authorised plumber can install and repair them.

Becoming an IQP allows plumbers to expand the work, which they are authorised to do. Testing is required every 12 months for many backflow prevention devices.

Therefore, becoming an IQP can add a regular income stream to a business. The territorial authority (e.g. your local council) determines who can become an IQP. Generally, a territorial authority will require training in backflow prevention then registering with them.

For more information, contact your local council.

Become registered in all three trades 

Become registered in all three trades (plumbing, gasfitting and drainlaying). Having an extra registration vastly increases your value to a company and the work, which you can do.

This can save your business and your client money by not having to outsource to other tradespeople in order to complete work that requires the different authorisations.

In the last few years, the Board has worked hard to create new pathways for people to become registered. This includes – the opportunity for oral examinations for people with learning difficulties; and the Skills Recognition of Current Competency (RCC) assessment for people that have been working in the trade for many years but never completed the formal training.

If you are not registered in all three trades (plumbing, gasfitting or drainlaying) contact the Boards registration team for advice on what pathway would be most suitable for your situation or the Skills organisation for information on training.

In some cases, the training for the national certificate in another trade may take as little as 2-2 ½ years.

Contact 0508 Skills (0508 754 557)

Contact the Board 0800 743 262


Service Agent

Becoming a service agent opens up the earning potential for a tradesperson and/or company.

Many manufacturers require people to be a service agent in order to do maintenance on their products.

A person may be legally authorised to do maintenance on some products but in many circumstances, unless they are a service agent they void the warranty on the product.

If a person or company are wanting to upskill and become a service agent, they should contact the manufacturer of the products they would like to service.

The manufacturer can guide them on what they require for someone to become a service agent for them.

0800 743 262

It's a hot-line to point you in the right direction.

If you are unsure, this is the support that will ensure you have all the information you need to help you get it right with essential decision making.